Free · English and ಕನ್ನಡ
Submersible Cable Size Calculator
Choose your motor and enter the pump depth in feet. See the submersible cable size (wire size) in sq mm that dealers commonly fit for a borewell, how much to buy, and how much voltage a thinner cable would lose before it burns your motor.

Not sure? Use the borewell motor HP calculator.HP ಗೊತ್ತಿಲ್ಲವೇ? HP ಕ್ಯಾಲ್ಕುಲೇಟರ್ ನೋಡಿ.
The depth stops where this motor can no longer lift water.ಈ ಮೋಟಾರ್ ನೀರು ಎತ್ತುವಷ್ಟು ಆಳದವರೆಗೆ ಮಾತ್ರ.
Cable size you needನಿಮಗೆ ಬೇಕಾದ ಕೇಬಲ್ ಸೈಜ್
2.5 sq mm
One 3 core flat copper cable, about 100 m long
Submersible pump cable size chart (sq mm by HP and depth)
The chart assumes the pump hangs at the depth shown and the starter is 30 feet from the borewell. A dash means that motor is too small to lift water from that depth, or single phase motors are not used that deep. The calculator only offers depths each motor can really work at, with normal cable sizes.
On a phone, swipe the chart sideways.
| Motor | 100 ft | 200 ft | 300 ft | 400 ft | 600 ft | 800 ft | 1000 ft | 1200 ft | 1400 ft |
|---|---|---|---|---|---|---|---|---|---|
| 3 phase, 3 HP, single cable | 2.5 sq mm | 2.5 sq mm | — | — | — | — | — | — | — |
| 3 phase, 5 HP, single cable | 2.5 sq mm | 2.5 sq mm | 4 sq mm | — | — | — | — | — | — |
| 3 phase, 7.5 HP, single cable | 4 sq mm | 4 sq mm | 6 sq mm | 6 sq mm | 6 sq mm | — | — | — | — |
| 3 phase, 10 HP, single cable | 4 sq mm | 4 sq mm | 6 sq mm | 6 sq mm | 6 sq mm | 6 sq mm | — | — | — |
| 3 phase, 7.5 HP, double cable (each cable) | 2.5 sq mm | 2.5 sq mm | 4 sq mm | 4 sq mm | 4 sq mm | — | — | — | — |
| 3 phase, 10 HP, double cable (each cable) | 2.5 sq mm | 2.5 sq mm | 4 sq mm | 4 sq mm | 4 sq mm | 4 sq mm | — | — | — |
| 3 phase, 12.5 HP, double cable (each cable) | 4 sq mm | 4 sq mm | 6 sq mm | 6 sq mm | 6 sq mm | 6 sq mm | — | — | — |
| 3 phase, 15 HP, double cable (each cable) | 4 sq mm | 4 sq mm | 6 sq mm | 6 sq mm | 6 sq mm | 6 sq mm | 6 sq mm | — | — |
| 3 phase, 20 HP, double cable (each cable) | 6 sq mm | 6 sq mm | 10 sq mm | 10 sq mm | 10 sq mm | 10 sq mm | 10 sq mm | — | — |
| 3 phase, 25 HP, double cable (each cable) | 6 sq mm | 6 sq mm | 10 sq mm | 10 sq mm | 10 sq mm | 10 sq mm | 10 sq mm | 10 sq mm | 10 sq mm |
| 3 phase, 30 HP, double cable (each cable) | 6 sq mm | 6 sq mm | 10 sq mm | 10 sq mm | 10 sq mm | 10 sq mm | 10 sq mm | 16 sq mm | 16 sq mm |
| Single phase, 2 HP | 2.5 sq mm | 4 sq mm | — | — | — | — | — | — | — |
| Single phase, 3 HP | 4 sq mm | 6 sq mm | — | — | — | — | — | — | — |
| Single phase, 5 HP | 6 sq mm | 10 sq mm | 10 sq mm | — | — | — | — | — | — |
For a short run, the simple table in our cable size guide gives the same sizes.
How to calculate cable size for a submersible pump
- Cable length: pump depth plus the distance from the borewell to the starter.
- Motor current: the usual full load current of a submersible motor of that HP, from a pump maker’s chart.
- Voltage lost: worked out for copper flat cable. The calculator picks the thinnest size that loses no more than about 7%, which is what dealers commonly fit for Indian borewell motors. Pump makers’ charts allow only about 3%, so they show thicker cable.
- Double cable: for star delta motors, each of the two cables carries part of the current, so each can be thinner than one single cable.
- Never thinner than our table: for short runs the answer is never thinner than the cable size table we publish.
A thin cable burns motors slowly
A cable that is too thin doesn’t fail on day one. It quietly drops the voltage, so the motor at the bottom gets less than the starter shows. The motor pulls more current to make up for it and runs hot, every day, until the winding gives up. That is why the cable is one of the common reasons submersible motors burn.
A BTCO digital starter shows the current on each phase, so a cable problem shows up as numbers before it shows up as a burnt motor. It also has cable fault and grounding protection, with dry run, overload and single phasing protection. See what Check Cable / Kit and the other starter messages mean, and why good earthing matters.
Tips before you buy cable
- Buy proper flat submersible cable with copper conductors, made for use under water.
- Both cables of a double cable motor must be the same size.
- If you are between two sizes, choose the thicker one. It loses less voltage and runs cooler.
- Lowering the pump deeper later? Check the cable again: it may now be too thin or too short.
- Have the joint at the motor made with a proper waterproof kit, and test the insulation before lowering the pump.
Not sure of your motor’s HP? Use the borewell motor HP calculator first.
Frequently asked questions
What cable size is needed for a 5 HP submersible pump?
For a 3 phase 5 HP motor, 2.5 sq mm for up to about 100 metres of cable (330 feet) and 4 sq mm for longer runs. A single phase 5 HP motor (a rare size; single phase stops at 5 HP) carries much more current: 6 sq mm for up to about 50 metres, 10 sq mm for longer runs.
What cable size for a 7.5 HP submersible pump?
For a 7.5 HP single cable motor, 4 sq mm for up to about 100 metres of cable and 6 sq mm for longer runs. A 7.5 HP double cable motor takes two cables of 2.5 sq mm (short runs) or 4 sq mm (longer runs).
What cable size for a 10 HP submersible pump at 600 feet?
With the starter 30 feet from the borewell, that is about 630 feet (192 metres) of cable. A 10 HP single cable motor needs about 6 sq mm. A 10 HP double cable motor needs two cables of about 4 sq mm each.
What size cable for a 25 HP motor at 1400 feet?
About two cables of 10 sq mm each, which is what dealers commonly fit. For a 30 HP motor at 1200 to 1400 feet, about two cables of 16 sq mm each.
Why do pump makers’ charts show a thicker cable than my dealer?
Pump makers’ charts allow only about 3% of the voltage to be lost in the cable. Indian borewell motors are built to run on low voltage, so dealers commonly fit thinner cable that loses up to about 7%. This calculator follows that common practice.
How do I work out the cable length?
Add the depth where the pump hangs and the distance from the borewell to the starter. Buy a little extra for the joint at the motor.
Why does a double cable motor need two cables?
A star delta motor has six leads instead of three, so it takes two 3 core cables. Both cables must be the same size. Each cable carries less current than a single cable would, so each one can be thinner.
What happens if the cable is too thin?
The cable loses voltage along its length, so the motor gets low voltage, pulls more current and runs hot. Over months this can burn the motor. You may see higher current than normal on the starter’s display, overload trips, or a warm cable at the top.
What does Check Cable / Kit mean on a BTCO starter?
The starter found a problem in the motor cable or in the contactor kit inside the starter. Ask an electrician to check the cable, its joints and the contactor kit. Our starter error messages guide has a video on it.
Please note: these are approximate values, not exact ones. They are general information, not a BTCO recommendation. Every borewell, motor and pump is different, so please contact your motor dealer for values made for your borewell before you buy. BTCO does not make or sell cable.