Submersible Pump Starters

A burnt submersible motor means a costly rewind and days without water. The right starter stops that from happening. Every BTCO starter is fully automatic and has dry run and overload protection, so it cuts the power before your motor burns. Made in Tumakuru, Karnataka, for 2 to 30 HP motors: DOL and star delta starters, Combined starters for juice line and 2 phase, single phase starters, and mobile control.

Download the brochures

ಈ ಪುಟದ ಸಾರಾಂಶ ಕನ್ನಡದಲ್ಲಿ ಓದಿ ↓

Protection in every BTCO starter

A submersible motor burns when it runs dry, runs on a missing phase, or draws too much current for too long. Every BTCO starter watches the motor and cuts the power before that happens. Here is what each starter has.

FeatureDOL-03FASD-03 Star DeltaCombined DOLCombined Star DeltaSingle PhaseMPAU
Fully automatic ON/OFFYesYesYesYesYesYes
Dry run protectionYesYesYesYesYesYes
Overload protectionYesYesYesYesYesYes
Single phasing protectionYesYesYesYes–Yes
Voltage fluctuation protectionYesYesYesYesLow and high voltageYes
Earth fault protectionYesYesYesYesYesYes
Cable and kit fault protectionYesYesYesYesYesYes
Rotor lock (jammed pump)––On 2 phase and juice lineOn 2 phase and juice line–Yes
Automatic capacitor management––YesYesShorted capacitor protection–
Timers (normal, cyclic, RTC)Timer + WLC variantTimer + WLC variantIn the app, with GSM ModuleIn the app, with GSM ModuleDomestic modelOptional
Water level controllerTimer + WLC variantTimer + WLC variant––Domestic modelOptional
Digital display: volts, amps, trip reasonYesYesYesYesYesYes
Mobile control (app + SMS)With GSM ModuleWith GSM ModuleWith GSM ModuleWith GSM ModuleWith GSM ModuleWith GSM Module
Runs on juice line / 2 phase––Yes, juice line up to 10 HP2 phase; juice line up to 10 HP––

DOL-03

Grey lines: not on this model.

  • Fully automatic ON/OFF
  • Dry run protection
  • Overload protection
  • Single phasing protection
  • Voltage fluctuation protection
  • Earth fault protection
  • Cable and kit fault protection
  • Rotor lock (jammed pump)
  • Automatic capacitor management
  • Timers (normal, cyclic, RTC)Timer + WLC variant
  • Water level controllerTimer + WLC variant
  • Digital display: volts, amps, trip reason
  • Mobile control (app + SMS)With GSM Module
  • Runs on juice line / 2 phase

FASD-03 Star Delta

Grey lines: not on this model.

  • Fully automatic ON/OFF
  • Dry run protection
  • Overload protection
  • Single phasing protection
  • Voltage fluctuation protection
  • Earth fault protection
  • Cable and kit fault protection
  • Rotor lock (jammed pump)
  • Automatic capacitor management
  • Timers (normal, cyclic, RTC)Timer + WLC variant
  • Water level controllerTimer + WLC variant
  • Digital display: volts, amps, trip reason
  • Mobile control (app + SMS)With GSM Module
  • Runs on juice line / 2 phase

Combined DOL

Grey lines: not on this model.

  • Fully automatic ON/OFF
  • Dry run protection
  • Overload protection
  • Single phasing protection
  • Voltage fluctuation protection
  • Earth fault protection
  • Cable and kit fault protection
  • Rotor lock (jammed pump)On 2 phase and juice line
  • Automatic capacitor management
  • Timers (normal, cyclic, RTC)In the app, with GSM Module
  • Water level controller
  • Digital display: volts, amps, trip reason
  • Mobile control (app + SMS)With GSM Module
  • Runs on juice line / 2 phaseYes, juice line up to 10 HP

Combined Star Delta

Grey lines: not on this model.

  • Fully automatic ON/OFF
  • Dry run protection
  • Overload protection
  • Single phasing protection
  • Voltage fluctuation protection
  • Earth fault protection
  • Cable and kit fault protection
  • Rotor lock (jammed pump)On 2 phase and juice line
  • Automatic capacitor management
  • Timers (normal, cyclic, RTC)In the app, with GSM Module
  • Water level controller
  • Digital display: volts, amps, trip reason
  • Mobile control (app + SMS)With GSM Module
  • Runs on juice line / 2 phase2 phase; juice line up to 10 HP

Single Phase

Grey lines: not on this model.

  • Fully automatic ON/OFF
  • Dry run protection
  • Overload protection
  • Single phasing protection
  • Voltage fluctuation protectionLow and high voltage
  • Earth fault protection
  • Cable and kit fault protection
  • Rotor lock (jammed pump)
  • Automatic capacitor managementShorted capacitor protection
  • Timers (normal, cyclic, RTC)Domestic model
  • Water level controllerDomestic model
  • Digital display: volts, amps, trip reason
  • Mobile control (app + SMS)With GSM Module
  • Runs on juice line / 2 phase

MPAU

Grey lines: not on this model.

  • Fully automatic ON/OFF
  • Dry run protection
  • Overload protection
  • Single phasing protection
  • Voltage fluctuation protection
  • Earth fault protection
  • Cable and kit fault protection
  • Rotor lock (jammed pump)
  • Automatic capacitor management
  • Timers (normal, cyclic, RTC)Optional
  • Water level controllerOptional
  • Digital display: volts, amps, trip reason
  • Mobile control (app + SMS)With GSM Module
  • Runs on juice line / 2 phase

Which starter does my motor need?

Find your starter in 10 seconds: check your motor's phase, cable and HP, and your power supply. Or answer a few quick questions in our starter finder. Not sure? Call or WhatsApp us with your motor's HP and we'll tell you.

  • BTCO DOL-03 fully automatic DOL starter for 3–10 HP single cable submersible motors

    3 phase motor, single cable, 3–10 HP, on 3 phase supply

    DOL-03 fully automatic DOL starter

    With or without timer + WLC. Dry run, single phasing, overload and voltage fluctuation protection.

  • BTCO FASD-03 fully automatic star delta starter for 7.5–30 HP double cable submersible motors

    3 phase motor, double cable, 7.5–30 HP, on 3 phase supply

    FASD-03 fully automatic star delta starter

    Star delta start for big motors, with or without timer + WLC, and the same full protection.

  • BTCO DOL-2/3 Combined juice starter for 3 phase motors on juice line, 2 phase or 3 phase

    3 phase motor, single cable, 3–10 HP, on juice line, 2 phase or 3 phase

    DOL-2/3 Combined juice starter

    Runs your 3 phase motor when the village supply is juice line or 2 phase, and manages the capacitors automatically.

  • BTCO FASD-2/3 Combined star delta starter for 2 phase and 3 phase supply

    3 phase motor, double cable, 7.5–25 HP, on 2 phase or 3 phase (juice line up to 10 HP)

    FASD-2/3 Combined star delta starter

    Star delta start on 2 phase or 3 phase supply; the 7.5–10 HP model also runs on juice line.

  • BTCO FASP-01 fully automatic single phase starter for 2–5 HP submersible pumps

    Single phase motor, 2–5 HP

    FASP-01 fully automatic single phase starter

    Domestic (2–3 HP) has a water level controller and timers for homes; Agro (2–5 HP) is for farm borewells. Low and high voltage protection.

  • BTCO MPAU auto start unit and motor protection device for 3 phase starters

    Auto start and motor protection unit, 3 phase, up to 30 HP

    MPAU auto start unit

    Automatic ON/OFF with dry run, single phasing, overload and voltage fluctuation protection, and a volts and amps display.

  • BTCO 4G GSM Module for mobile control of the starter by app and SMS

    You want to switch the motor from your phone

    GSM Module (mobile starter)

    Fits any BTCO starter: switch ON/OFF by app or SMS, and get alerts for power cuts and trips.

ಕನ್ನಡದಲ್ಲಿ: ನಿಮ್ಮ ಮೋಟಾರ್‌ಗೆ ಯಾವ ಸ್ಟಾರ್ಟರ್?

ತಪ್ಪು ಸ್ಟಾರ್ಟರ್‌ನಿಂದ ಸಬ್‌ಮರ್ಸಿಬಲ್ ಮೋಟಾರ್ ಸುಟ್ಟು ಹೋಗುತ್ತದೆ. ಪ್ರತಿ BTCO ಸ್ಟಾರ್ಟರ್ ಫುಲ್ಲಿ ಆಟೋಮ್ಯಾಟಿಕ್, ಮತ್ತು ಅದರಲ್ಲಿ ಡ್ರೈ ರನ್ ಮತ್ತು ಓವರ್‌ಲೋಡ್ ರಕ್ಷಣೆ ಇದೆ: ಮೋಟಾರ್ ಸುಡುವ ಮೊದಲೇ ಕರೆಂಟ್ ಕಟ್ ಮಾಡುತ್ತದೆ. ಕೆಳಗಿನ ಪಟ್ಟಿಯಲ್ಲಿ ನಿಮ್ಮ ಮೋಟಾರ್ ಹುಡುಕಿ.

ನಿಮ್ಮ ಮೋಟಾರ್ನಿಮ್ಮ ಲೈನ್BTCO ಸ್ಟಾರ್ಟರ್
3 ಫೇಸ್ ಮೋಟಾರ್, ಸಿಂಗಲ್ ಕೇಬಲ್, 3–10 HP3 ಫೇಸ್DOL-03 ಫುಲ್ಲಿ ಆಟೋಮ್ಯಾಟಿಕ್ DOL ಸ್ಟಾರ್ಟರ್
3 ಫೇಸ್ ಮೋಟಾರ್, ಡಬಲ್ ಕೇಬಲ್, 7.5–30 HP3 ಫೇಸ್FASD-03 ಫುಲ್ಲಿ ಆಟೋಮ್ಯಾಟಿಕ್ ಸ್ಟಾರ್ ಡೆಲ್ಟಾ ಸ್ಟಾರ್ಟರ್
3 ಫೇಸ್ ಮೋಟಾರ್, ಸಿಂಗಲ್ ಕೇಬಲ್, 3–10 HPಜ್ಯೂಸ್ ಲೈನ್, 2 ಫೇಸ್ ಅಥವಾ 3 ಫೇಸ್DOL-2/3 ಕಂಬೈನ್ಡ್ (ಜ್ಯೂಸ್) ಸ್ಟಾರ್ಟರ್
3 ಫೇಸ್ ಮೋಟಾರ್, ಡಬಲ್ ಕೇಬಲ್, 7.5–25 HP2 ಫೇಸ್ ಅಥವಾ 3 ಫೇಸ್ (10 HP ವರೆಗೆ ಜ್ಯೂಸ್ ಲೈನ್ ಕೂಡ)FASD-2/3 ಕಂಬೈನ್ಡ್ ಸ್ಟಾರ್ ಡೆಲ್ಟಾ ಸ್ಟಾರ್ಟರ್
ಸಿಂಗಲ್ ಫೇಸ್ ಮೋಟಾರ್, 2–5 HPಸಿಂಗಲ್ ಫೇಸ್FASP-01 ಸಿಂಗಲ್ ಫೇಸ್ ಸ್ಟಾರ್ಟರ್ (ಡೊಮೆಸ್ಟಿಕ್ 2–3 HP, ಆಗ್ರೋ 2–5 HP)
ಫೋನ್‌ನಿಂದ ಮೋಟಾರ್ ON/OFF ಮಾಡಬೇಕೇ?ಯಾವುದೇ BTCO ಸ್ಟಾರ್ಟರ್‌ಗೆBTCO GSM ಮಾಡ್ಯೂಲ್ (ಆಪ್ ಮತ್ತು SMS)

7.5 ಅಥವಾ 10 HP ಮೋಟಾರ್ ಸಿಂಗಲ್ ಕೇಬಲ್ ಅಥವಾ ಡಬಲ್ ಕೇಬಲ್ ಆಗಿರಬಹುದು: ಮೋಟಾರ್‌ನ ಕೇಬಲ್ ಎಣಿಸಿ ನೋಡಿ.

ಕೆಲವು ಪ್ರಶ್ನೆಗಳಿಗೆ ಉತ್ತರಿಸಿ ಸರಿಯಾದ ಸ್ಟಾರ್ಟರ್ ನೋಡಲು ಸ್ಟಾರ್ಟರ್ ಫೈಂಡರ್ ಬಳಸಿ (ಕನ್ನಡ ಆಯ್ಕೆ ಇದೆ). ಮೋಟಾರ್ ಯಾಕೆ ಸುಡುತ್ತದೆ ಎಂದು ಕನ್ನಡದಲ್ಲಿ ಓದಿ.

Stop your motor from burning

A rewind costs far more than a good starter. Read why submersible motors keep burning.

Mobile control for any BTCO starter

Fit the BTCO GSM Module and your starter becomes a mobile starter: switch the motor ON or OFF from the free app or by SMS, set timers, and get alerts for power cuts and trips, with the reason.

Before you call us

Tell us these and we'll suggest the right starter and give you all the details:

  • Your motor's HP
  • Single cable or double cable motor (or single phase motor)
  • Your power supply: 3 phase, 2 phase, juice line or single phase
  • Do you want timers or a water level controller?
  • Do you want to switch the motor from your phone?

Frequently asked questions

Which starter do I need for my submersible motor?

It depends on three things: your motor (single phase or 3 phase), its cable (single cable or double cable) and your power supply. For a 3 phase single cable motor up to 10 HP on 3 phase supply, take the DOL-03. For a double cable motor from 7.5 to 30 HP, take the FASD-03 star delta starter. On juice line or 2 phase supply, take a Combined DOL or Combined star delta starter. For a single phase motor, take the FASP-01.

Which starter for a 5, 7.5, 10, 15, 20 or 30 HP submersible motor?

A 5 HP 3 phase single cable motor takes the DOL-03, and a 5 HP single phase motor takes the FASP-01 Agro. At 7.5 and 10 HP, a single cable motor takes the DOL-03 and a double cable motor takes the FASD-03 star delta. From 12.5 HP up to 30 HP (15, 20, 25 HP) the motor is double cable and takes the FASD-03. On juice line or 2 phase supply, use the Combined starters instead (juice line only up to 10 HP).

What is the difference between single cable and double cable motors?

A single cable motor has one cable with 3 wires and starts directly on line (DOL). A double cable motor has two cables, 6 wires, and starts in star and then changes to delta, which is gentler for big motors. Bigger motors, usually from 7.5 HP, are double cable and need a star delta starter.

Can a 3 phase motor run on 2 phase or juice line?

Yes, with a BTCO Combined starter. The Combined DOL runs a 3 phase single cable motor up to 10 HP on juice line, 2 phase or 3 phase. The Combined star delta runs double cable motors up to 25 HP on 2 phase or 3 phase, and on juice line only up to 10 HP. Above 10 HP, juice line is not safe for the motor.

Do BTCO starters protect the motor from burning?

Yes, that is what they are made for. Every BTCO starter has dry run and overload protection, and the 3 phase starters stop the motor when a phase goes missing. They trip on the motor current, so they also give voltage fluctuation protection; the Single Phase starter adds low and high voltage protection. See every protection in our submersible motor protection guide.

Can I add mobile control later?

Yes. Fit the BTCO GSM Module to any BTCO starter bought from January 2024 onwards and switch the motor from the app or by SMS. If your starter is older, call us to check first. See how a mobile starter works.

How much does a BTCO starter cost?

The price depends on the model, the HP and the variant (with or without timer + WLC). Call or WhatsApp us with your motor's HP and supply, and we'll give you all the details.

What is the warranty?

BTCO starters come with a 1 year warranty (on the DOL-03 and FASD-03 it covers the MPAU unit). Capacitors have a 6 month warranty. See the warranty tab on each product page for the details.

Where can I buy a BTCO starter?

From BTCO dealers across Karnataka. Find your nearest sales and service centre, or call us and we'll tell you.

Share our Products on Social Media: